TOA VM2240 System Amplifier

£995.00 EX VAT

Description

Product Features:

  • 120W or 240W
  • Programmable system management amplifier
  • Emergency power input, remote power control & 7 built-in chimes
  • 5 switchable high impedance speaker zones – adjustable attenuators
  • Routing to the zones of the 3 Microphone/Line Level inputs and telephone paging input can be pre-set

Application Examples:

  • Museums
  • Auditoriums
  • Conference rooms
  • Houses of worship
  • Health & fitness clubs

Specifications:

VM-2240

VM-2120

Power Source

230V AC
50/60 Hz
230V AC
50/60 Hz

Rated Output

Total: 5 zones @ 240W
Total: 5 zones @ 120W

Frequency

Response

50 Hz – 16 kHz
50 Hz – 16 kHz

Distortion

< 1 %
< 1 %

Power

Consumption

54W – No Output
549W @ R.O
37W – No Output
201W @ R.O

Current

Consumption

14 A
5.2 A

S/N Ratio

60 dB
60 dB

Inputs

Telephone (-10 dBV, balanced), x1
MIC (-60 dBV) /LINE (-10 dBV), balanced, x3
BGM (-20 dBV, unbalanced, stereo RCA jacks), x2
  • 100V, x1
Telephone (-10 dBV, balanced), x1
MIC (-60 dBV) /LINE (-10 dBV), balanced, x3
BGM (-20 dBV, unbalanced, stereo RCA jacks), x2
  • 100V, x1

Outputs

Line: (0 dBV, unbalanced, RCA jack), x1
Recording: (0 dBV, unbalanced, RCA jack), x1
Preamplifier: (0 dBV, unbalanced, RCA jack), x1
  • Direct Speaker Output, x1
  • Speaker Lines w/ Attenuator – selectable, x5
Line: (0 dBV, unbalanced, RCA jack), x1
Recording: (0 dBV, unbalanced, RCA jack), x1
Preamplifier: (0 dBV, unbalanced, RCA jack), x1
  • Direct Speaker Output, x1
  • Speaker Lines w/ Attenuator – selectable, x5

Control Input

Contact Input:
Open Voltage: 3.3V DC
Short-circuit Current1 mA
Activation of Inputs 1-3, x3

 

25-pin female D-sub connector:
  • Activation of power
  • Unit’s broadcast cut-off
  • Activation and stop of emergency broadcast
  • Activation of messages (when EV-200M is installed), x5
Contact Input:
Open Voltage: 3.3V DC
Short-circuit Current1 mA
Activation of Inputs 1-3, x3

 

25-pin female D-sub connector:
  • Activation of power
  • Unit’s broadcast cut-off
  • Activation and stop of emergency broadcast
  • Activation of messages (when EV-200M is installed), x5

Control Output

5 relay contacts for External Attenuator Control
Open Collector Output:
Withstand Voltage: 30V DC
Operating Current: under 10 mA

 

25-pin female D-sub connector:
  • Power Switch on
  • AC power condition
  • DC power condition
  • Failure (FAULT) indication on
  • Irregularity of the sound source of the Voice Announcement Board
  • Irregularity of communications with the Remote Microphone and an expansion amplifier
5 relay contacts for External Attenuator Control
Open Collector Output:
Withstand Voltage: 30V DC
Operating Current: under 10 mA

 

25-pin female D-sub connector:
  • Power Switch on
  • AC power condition
  • DC power condition
  • Failure (FAULT) indication on
  • Irregularity of the sound source of the Voice Announcement Board
  • Irregularity of communications with the Remote Microphone and an expansion amplifier

Indicator

Zone, all-call, emergency, fault, power, 5-step level bargraph
Zone, all-call, emergency, fault, power, 5-step level bargraph

Operating

Temperature

0 °C – 40 °C
0 °C – 40 °C

Finish

ABS resin, steel plate, paint, dark grey
ABS resin, steel plate, paint, dark grey

Dimensions

419 mm W x 143.3 mm H x 355.7 mm D
419 mm W x 143.3 mm H x 355.7 mm D

Weight

14.5 kg
12.5 kg

Accessories (Included)

  • VR Cover, x4
  • Spare Fuse, x1
  • Power Cord, x1
  • Name Label, x1
  • VR Cover, x4
  • Spare Fuse, x1
  • Power Cord, x1
  • Name Label, x1

Data Sheets

Brochure
Data Sheet

Additional information

Manufacturer

TOA

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

You may need these too ...